发行说明
4.0.2.6
2014/4/23
Install
- Updated the ClientAce binaries to version 4.0.2.6.
- Added support for Visual Studio 2013 IDE.
- Added the following new examples:
- Simple ClientAce OPC DA VS2010-12 Event Example_VB
- Simple ClientAce OPC DA VS2010-12 Event Example_CS
- Complex ClientAce OPC DA VS2010-12 Example_VB
- Tested support for the .NET 4.5 Framework.
- Added installer and files for the Visual Studio 2010 C++ Runtime and OPC Foundation Core redistributables.
ClientAce Binaries
- Corrected an error that caused AsyncWrite to sporadically throw IndexOutOfBounds exceptions.
- Corrected an error that caused OPC UA Connect to hang when the targeted server either did not support or had not enabled the security settings specified in the ConnectInfo object.
- Fixed the ReadCompleted and WriteCompleted callback functions so that they return results for each item even if there is a timeout while performing the Read or Write actions (or if the complete operation failed).
- Added the new status code E_Timeout.
4.0.2.2
2013/7/16
- Added support for the .NET 4.0 Framework in Visual Studio 2010 and Visual Studio 2012.
- Added support to the ClientAce API that allows ClientAce applications to be developed as OPC UA Clients (for DA Information Models only). ClientAce supports all OPC UA security levels, direct connections to endpoints, and browsing for endpoints via Local Discovery Servers.
- Added support to the DA Junction that allows users to connect to OPC UA endpoints directly or to browse for local OPC UA endpoints via Local Discovery Servers.
- Added support to the ServerBrowser Control for OPC UA server browsing via Local Discovery Servers.
- Added support to the ItemBrowser Control for OPC UA server connection and OPC Item browsing.
- Added support for UA user authentication through the passing of username and password credentials to the OPC UA server.
- Updated the Kepware-specific ServerState Control. There are now two controls: one for OPC DA and one for OPC UA. The Server Project Name field was removed from the control, and the Server Project Title field was added.
- Updated the Kepware-specific ChannelSetting Control. There are now two controls: one for OPC DA and one for OPC UA. The controls were updated to support the new channel and device properties that were added during updates to KEPServerEX V5. Newly supported fields include Pending Reads/Writes and Max Pending Reads/Writes for diagnostics, Media Level Redundancy monitoring tags, device-level diagnostics tags, Scan Modem, and Ethernet Encapsulation.
- Added support to the ClientAce API that allows ClientAce applications to be developed as OPC XML-DA clients.
- Made an enhancement that allows users to force ClientAce to only use the OPC 3.0 IOPCBrowse Method or the OPC 2.0 IOPCBrowseServerAddressSpace Method. In the default setting, the ClientAce API queries the OPC Server to determine the OPC specification it supports and then uses the appropriate browse method; however, some OPC servers do not properly indicate the specifications that they support.
- Added support for the IOPCCommon::SetClientName Method. For servers that support this on the OPC interface, this method allows a client application to identify itself to the server application in addition to the ClientID. Support for IOPCCommon::SetClientName was added to KEPServerEX versions 5.7 and later.
4.0.2.13
2015/6/23
- Updated the libraries to version 4.0.2.7.
- Added support during installation for Roaming Profiles with remote servers. Add-in Install location is now relative to the target directory selected during installation and is visible within Visual Studio's Add-in Options. Some users may be required to uninstall the product before upgrading to remove any Add-ins previously installed in the default location.
- Added new properties to the ConnectInfo class that support configurable timeouts for UA Service calls and adding read/write groups with active items.
- Updated DA Junction control to sample at the same rate as the publishing interval instead of sampling as fast as possible.
- Fixed an issue where the revised update rate was not set when creating a subscription on an underlying OPC UA server.
- Corrected an error causing an exception when removing a server through the ServerBrowser control.
- Fixed a memory leak with applications using the asynchronous methods ReadAsync / WriteAsync without binding to a ReadCompleted / WriteCompleted event.
- Resolved an issue where license requests on certain operating systems (Windows 7 or higher) could not be validated.
3.5.0.9
2012/2/21
- Updated ClientAce binaries to address a low-level threading issue that could result in orphaned threads for callbacks.
- Updated the VB .Net examples.
- Added two new C# examples.
- Fixed an installation issue that occurred when the user selected "Yes" in the "Disable Support for this version of Microsoft Visual Studio" prompt during the installation.
3.5.0.3c
2010/12/22
- Added Support for Microsoft Visual Studio 2010
3.5.0.3
2009/10/6
- Added Support for Microsoft Visual Studio 2008.
- Added Microsoft Visual Studio 2008 ClientACE components.
- Updated Visual Studio 2003 and 2005 ClientACE components to version V1.1.0.15. This update addresses anomaly with datatype sent by some OPC servers.
- Added 3 Microsoft Visual Studio 2008 examples: Simple and Complex ClientAce VS2008 Examples, plus Simple ClientAce DA_Junction VS2008 Example.
- Separated 3 Visual Studio examples into separate components and install Example only if corresponding Visual Studio is detected. For example, if only Visual Studio 2008 is detected, then only Visual Studio 2008 example will be installed.
- Setup now requires a minimum of Microsoft Visual C# Language installed to Microsoft Visual Studio to enable adding of ClientAce Components to Visual Studio Toolbox.
- Updated the help file for VS2008 and Vista specific requirements.
- Updated the help file for changes in the OPC Items class, the properties are now a list array vs. an object array.
- Update the help file with descriptions of the properties, methods, and events associated with the Server Browser, Item Browser, and DA Junction class objects.
- Updated the help file with example code showing how to use the Server Browser, Item Browser, and DA Junction in a project.
- Updated the License utility with new e-mail address for support rather than sales.
- Updated the License Agreement.
- Fixed issue where using ClientAce objects in forms that are a custom derived class cause them to fail with an exception.
更多技术信息
开发环境支持
- .NET 4.0/4.5
- Visual Studio 2010 和更高版本
有关支持 Visual Studio 2008 的信息,请联系我们寻求技术支持,电话 021-6482 6558 。
硬件要求
请参考 Visual Studio 项目中将使用的 Microsoft .NET Framework 版本的硬件要求:
- 100 MB 可用磁盘空间
- Microsoft Visual Studio 要求
部署使用 ClientAce 创建的自定义客户端应用程序时,.NET Framework 要求根据用于开发的 Visual Studio 版本而定。有关更多信息,请参考 ClientAce 产品手册中的“部署您的客户端应用程序”主题。
运行环境要求
Visual Studio 2010 C++ 运行环境可再发行组件
- ClientAce 的部分低级 OPC 层是在 Visual Studio 2010 中使用 C++ 编写的。因此,ClientAce 对于该版本的可再发行组件有一定的依赖性。部署使用 ClientAce 创建的自定义客户端应用程序时,这些文件都必须存在。这些可再发行组件的安装程序可在 ClientAce 安装文件夹中找到。
OPC Foundation 核心可再发行组件
- OPC DA 客户端/服务器连接需要 OPC Foundation 核心可再发行组件,后者通常在向操作系统安装 OPC 客户端或服务器时安装。在从未安装 OPC 客户端或服务器的 PC 上部署使用 ClientAce 创建的自定义客户端应用程序时,必须安装这些组件才能使之运行。OPC Foundation 核心可再发行组件的安装程序可在 ClientAce 安装文件夹中找到。
软件要求
要使应用程序按设计运行,需要满足以下要求:
- ClientAce 和用于开发 ClientAce 应用程序的 Microsoft Visual Studio 开发环境对 Microsoft Windows 操作系统的要求相同。如果使用的 Visual Studio 版本的操作系统要求没有列出预期使用的操作系统,则不支持在该操作系统上使用 ClientAce。
Windows Vista 和 Windows 7 上的 UAC
- 为确保所有组件在设计环境中正确运行,请在使用的计算机上关闭 UAC,以便通过 ClientAce 开发应用程序。
- UAC 限制对设计环境中的文件夹和文件的访问,这将影响设计环境中的某些对象。UAC 不影响运行环境中的这些对象。